30kW 33kW 36kW 40kW Three Phase On-Grid Solar Inverter
- Loading Port:
- China main port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 30 unit
- Supply Capability:
- 500 unit/month
- OKorder Service Pledge
- Quality Product
- Order Online Tracking
- Timely Delivery
- OKorder Financial Service
- Credit Rating
- Credit Services
- Credit Purchasing
Item specifice
CNBM 30kW 33kW 36kW 40kW Three Phase On-Grid Solar Inverter PV Solution
XG30kW-40kW Three Phase On-Grid Solar Inverter
XG30KTR | XG33KTR | XG36KTR | XG40KTR | |
Input(DC) | ||||
Max. Input Power | 48 kW | 52.8 kW | 57.6 kW | 64 kW |
Max. Input Voltage | 1100V | |||
Start Voltage | 250V | |||
Rated Input Voltage | 600V | |||
Full-load MPP Voltage Range | 500V-800V | |||
MPPT Voltage Range | 200V-1000V | |||
Number of MPP Trackers | 3 | 4 | ||
String per MPPT | 2 | |||
Max.Current per MPPT | 26A | |||
Max.Short Circuit Current per MPPT | 32A | |||
Output(AC) | ||||
Max. Output Current | 48.3 A | 53 A | 57.8 A | 64.3 A |
Rated Output Power | 30 kW | 33 kW | 36 kW | 40 kW |
Max. Output Power | 33.3 kVA | 36.6 kVA | 39.6 kVA | 44 kVA |
Rated Grid Frequency | 50 Hz / 60 Hz | |||
Rated Grid Voltage | 230Vac / 400Vac, 3L / N / PE | |||
Power Factor | >0.99 (0.8 leading~0.8 lagging) | |||
THDi | <3% (Rated Power) | |||
Efficiency | ||||
Max. Efficiency | 98.60% | |||
European Efficiency | 98.50% | |||
MPPT Efficiency | 99.90% | |||
Protection | ||||
DC reverse polarity protection | Yes | |||
Anti-Islanding protection | Yes | |||
AC short circuit protection | Yes | |||
Residual current monitoring unit | Yes | |||
Insulation resistance monitoring | Yes | |||
Ground fault monitoring | Yes | |||
Grid monitoring | Yes | |||
PV string monitoring | Yes | |||
Surge protection | Type II | |||
AFCI protection | Optional | |||
Communication | ||||
Display | LED / LCD / WiFi+App | |||
Communication | Standard:RS485 Optional:WiFi / GPRS / Ethernet | |||
Standard Compliance | ||||
Grid Connection Standards | IEC 61727, IEC 62116, IEC 60068, IEC 61683, VDE-AR-N 4110:2018, VDE-AR-N 4105:2018, VDE-AR-N 4120:2018, EN 50549, AS/NZS 4777.2:2020, CEI 0-21, VDE0126-1-1/A1 VFR 2014,UTE C15-712-1:2013, DEWA DRRG, NRS 097-2-1, MEA/PEA, C10/11, G98/G99 | |||
Safety/EMC | IEC 62109-1:2010, IEC 62109-2:2011, EN 61000-6-2:2005, EN 61000-6-3:2007/A1:2011 | |||
General Data | ||||
Dimensions (W*H*D) | 600 x 430 x 230 mm | |||
Weight | 30 kg | 32 kg | ||
Operating Temperature Range | -30° C ~ +60° C | |||
Cooling Method | Smart Cooling | |||
Protection Degree | IP66 | |||
Max. Operating Altitude | 4000 m | |||
Relative Humidity | 0 ~ 100% | |||
Topology | Transformerless | |||
Night Power Consumption | < 1 W |
MARKETING & SERVICE NETWORK
CNBM global sales team provides customers with professional and efficient pre-sale,
in sale and after-sale services, and enhances the added value of the brand with high-quality services.
Products Details:
High voltage protection Over load protection
Battery reverse connected protection Dust-proof
Low voltage protection Overheating protection
Output short-circuit protection Insect prevention
- Q:What is the difference between a PV grid-connected inverter and an off-grid inverter?
- Grid-connected inverter does not need energy storage, but the energy can not be controlled, the number of photovoltaic sent to send online how much, simply do not want people to.
- Q:Three-phase photovoltaic inverter grid, the use of phase-locked loop is what?
- Photovoltaic inverters for grid-connected photovoltaic power generation systems are primarily capable of receiving DC power from photovoltaic arrays and converting them into sine-wave currents of the same frequency and in phase with the access grid for powering the grid or local loads.
- Q:In a photovoltaic grid-connected project, the role of the inverter is to convert the voltage into AC 220V or 380V for the grid, since the transformer will raise the voltage again
- Part of the distributed grid-connected projects, the basic are "spontaneous use, the power of the Internet," these do not need to boost, because the extra power is actually consumed by the surrounding electricity users, do not boost to a Level power grid;
- Q:What is the difference between a grid-connected inverter and an off-grid inverter? What are the advantages of a hybrid inverter?
- Grid-connected inverter will be directly sent to the power grid, so to track the frequency of the grid, phase, the equivalent of a current source. Of course, there are some inverters that have a low-pressure through the ability to do PQ adjustment.
- Q:The function of photovoltaic grid - connected inverter
- In general, single-phase h-bridge is a common configuration of dc / ac-level, but can also be used in three-phase and other configurations.
- Q:Grid-connected inverter is generally divided into photovoltaic power generation grid-connected inverter, wind power grid-connected inverter, power equipment and grid-connected inverter and other power generation equipment power generation inverter.
- The grid inverter is a current source, the output voltage is basically the grid voltage, may be slightly raised.
- Q:What are the methods of photovoltaic grid-connected inverter control
- Sine wave output inverter control integrated circuits, sine wave output of the inverter, the control circuit can be used microprocessor control, such as INTEL company produced 80C196MC, Motorola produced MP16 and MI-CROCHIP company PIC16C73 and so on, these single-chip microcomputer has a multi-channel PWM generator,
- Q:Photovoltaic grid-connected inverter without DC emc how will happen
- by means of energy converters can be converted into electrical energy. The process of converting light energy directly into electrical energy is precisely the response to photovoltaic effects. Without the need for any other mechanical parts, the energy in
- Q:What is the difference between low voltage grid connection and medium voltage grid connection?
- When the power grid failure or disturbance caused by the power supply and network voltage drop, in the voltage drop range, the power group can be uninterrupted through the inverter and network operation.
- Q:Generally a large grid-connected photovoltaic power plant will have several inverters
- , This method is simple to design, easy maintenance, but also for the power grid harmonics smaller, good power quality!
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Similar products
New products
Hot products
Hot Searches
Related keywords
You Might Also Like